PZH R1 PV/1500/12,5 S

Code: 7710478

PZH R1 PV/1500/12,5 S

Code: 7710478

Lightning impulse current and surge arresters type T1+T2 intended for photovoltaic systems (PV) at U or Y connection. The advantage of the Y connection versus the U connection is the resistance to the earth connection of the working conductors and zero residual (leakage) current through the PE conductor. Particular varistor sectors, connected between the terminals L+, L- and PE are equipped with internal disconnectors, which are activated when the varistors fail (overheat). These devices are necessary to be used with the back-up fuse with external disconnector, which is intended for PV applications. They are installed on the DC side in PV applications with external LPS, where a sufficient distance "s" is not observed. Suitable for level LPL I or II. Ensure the equipotential bonding of plus and minus busbars of PV systems and the elimination of transient overvoltage resulting from the atmospheric discharges (including direct lightning strike to the PV system) or switching processes. S indication specifies a version with remote monitoring.

TECHNICAL DATA AND STANDARDS

LEGEND

MATERIAL


LABEL
MATERIAL
Rf
stainless steel
Rf*H4
acid-resistant stainless steel
Cu
copper
Al
aluminium
Fe
steel
FeZn
galvanized steel
FeZn-H
hot-dip galvanized sheet metal
KFe
polypropylen
FeCu
copper coated steel
Me
brass
PE
polyetilen - UV resistant
N
nylon – UV resistant
P-SV
polyester with UV resistant glass fibres
pvc
electrostatic plastic-coated
PVC
resistant synthetic material
Wood
wood
Concrete
concrete
Ltž
cast iron
CuSn
tinned copper
PP
polypropylen

CONDUCTOR DIMENSIONS

(appropriateness of holders for a certain profile of conductors)

LABEL
DESCRIPTION
Φ

round cross-section conductor

P

rectangular cross-section conductor


CONDUCTOR ATTACHMENT ON FASTENER

LABEL

DESCRIPTION

N

attachment with nylon attachment elements

PE

attachment with polyetilen attachment elements

K
click attachment system
V
screw attachment
*
upon request
Labels legend

Lightning impulse current and surge arresters type T1+T2 intended for photovoltaic systems (PV) at U or Y connection. The advantage of the Y connection versus the U connection is the resistance to the earth connection of the working conductors and zero residual (leakage) current through the PE conductor. Particular varistor sectors, connected between the terminals L+, L- and PE are equipped with internal disconnectors, which are activated when the varistors fail (overheat). These devices are necessary to be used with the back-up fuse with external disconnector, which is intended for PV applications. They are installed on the DC side in PV applications with external LPS, where a sufficient distance "s" is not observed. Suitable for level LPL I or II. Ensure the equipotential bonding of plus and minus busbars of PV systems and the elimination of transient overvoltage resulting from the atmospheric discharges (including direct lightning strike to the PV system) or switching processes. S indication specifies a version with remote monitoring.

There are currently no files available in your language

Website name

Contact detail

Hermi, d.o.o.

Trnoveljska cesta 15

3000 Celje

Slovenia